VIRTUAL PRACTICE LAB 03

Control the energy.
Verify the protection.

Hazardous Energy Control—LOTO. Follow a fictional machine procedure, apply personal locks, and make decisions from the evidence.

Free practiceBETA testAbout 20–30 minutes
LAB BENCH / 0 of 4 stations complete
Start with the machine-specific procedure.

SIMULATED PRACTICE RECORD

Read the evidence before release.

View the decision and equipment log

    KEEP LEARNING

    Connect the procedure to the work.

    Next practical · Hazard Communication / Chemical Safety →

    LOTO-001-AUTH · Authorized Employee Knowledge
    LOTO-001-AFF · Affected Employee Instruction
    LOTO-001-OTHER · Other Employee Awareness

    Separate report-reading resource · Its worked example is noise. Here, practice reading equipment identity, scope, controls, evidence, changed conditions and disposition in a verification record.

    Practice stays in this browser when storage is available. No learner/account results are transmitted. This supplement awards no course credit, certificate, authorized-employee designation or equipment qualification.

    Fictional procedure, scope & primary sources

    EC-03 v1 · supplied teaching assumptions

    M-03, its interlocked transfer machine, procedure, people, devices, records and readings are fictional. E-1 is the specified lockable electrical disconnect; A-1 is the specified lockable air-isolation valve. The example inputs are 480 V supply, 90 psi air and an 80 kg raised head. These are descriptive teaching inputs, not field specifications or device ratings.

    A compatible personal lock/ID-tag arrangement, correctly rated restraint R-03, pressure indication P-03, safe remote bleed and outside-access mechanical lowering fixture are supplied assumptions. R-03 is installed without anyone beneath the raised head. It is secured before pressure relief. Restoration lowers the head mechanically to a stable rest with electrical and air isolation still locked; it does not require energizing this fictional machine. Actual equipment requires its own designed and verified method.

    Electrical record Q-17 is provided by a fictional qualified person. The learner reviews the record; no probes, energized conductors, cabinet access or live electrical-testing instructions are simulated. A control try and pressure gauge are not absence-of-voltage testing. The pressure challenge supplies a 15 psi reaccumulation event and a separate protected correction record with fresh post-correction electrical evidence Q-17R; no learner fault repair is simulated. Continued verification is required in real work wherever hazardous reaccumulation is possible.

    The restoration station is a separate two-person scenario with a supplied shared-hasp arrangement at both isolators. Alex and Jordan each retain control of their own personal devices. The coworker event represents Jordan removing Jordan’s devices. Exceptional absent-person removal, group lockboxes, shift transfers, temporary energization for testing, tagout-only protection and industry-specific schemes require their own procedures and are not fully practiced here.

    Primary sources

    Source check: October 27, 2026. AI-assisted development. Independent technical, accessibility and learning validation remain pending. Use employer/manufacturer procedures and applicable jurisdiction/industry requirements for real work. No OSHA or manufacturer endorsement is claimed.

    U.S. Government source material

    Academy claims no copyright in original works of the U.S. Government. Original Government material remains attributed to its source and available free. The Academy’s original interface, simulations and fictional cases are separate. Use does not imply Government or manufacturer endorsement.